SPECIFICATIONS :
Gauge classification : Standard Chamber, Large Chamber
or Weld pad
Gauge Glass : Tempered borosilicate (Local Klinger / Maxos)
in 30mm width as standard.
Cushion : CAF
Gasket : CAF, PTFE , GROFOIL
Body (Liquid Chamber) : MS, CS (EN-8),ASTM A-105, SS304,
SS316 or PP
Cover Plate : MS, CS (EN-8),ASTM A-105, SS304, SS316 or PP
Bolts / Nuts : MS or Graded Alloy Steel for high temperature
service.
CC Distance : 1915mm for Straight Through / 1875mm for Hook
Up in single length. Extended Ranges through a coupler.
Gauge Connection : Straight Through / Hook - Up.
Process Connection (PC) : Flanged to BS, ASA, ANSI or DIN
/ Screwed to BSP or NPT.
Orientation (PC) : Top / Bottom : Left, Right, Rear, Vertical
Isolating Valves : Integral Offset Needle Valves / Inline
Ball / Globe Valve.
Vent : Plug
Drain : Plug / Needle / Ball / Globe Valve
Calibrated Scale : Al/ SS Linearly calibrated for level values
in mm (LC=10mm)
Special Features : Autoball Check, Frost Free, Internal Heating
/ Cooling
Test Pressure: (Kg/cm Sq) at ambient temperature : 0-30 (Local
glass), 0-160 (Klinger / Maxos)
Max. Temperature(C) : 0-125 (Local glass), 0-400 (Klinger
/ Maxos)
|
ORDERING
INFORMATION :
Specify range (CC Dist), Liquid, Optg temperature, pressure &
Viscosity. |
APPLICATIONS
:
Caustics, HF acids & any other glass attacking liquids, dirty
& viscous liquids in pressurised tanks |